0

Solar PCU

Solar PCU
Solar PCU
Price And Quantity
  • 1
  • Piece/Pieces
  • 15000 INR
Product Specifications
  • Galvanized Steel
  • IP65
  • Painted
  • 500 Grams (g)
  • Green
  • 16 months
    Product Description

    Main Functional Features of Solar Charge Controllers:

    • 2KW/3KW/5KW On-Grid Inverter with Energy Storage
    • Self-consumption and Feed-in to the grid
    • Programmable supply priority for PV, Battery or Grid
    • User-adjustable battery charging current suits different types of batteries
    • Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
    • Built-in Timer for various mode of on/off operation
    • Multiple communication for USB, RS-232, Modbus and SNMP
    • Monitoring software for real time status display and control

    Specifications:

     MODEL

    GEESYS 2KW

    GEESYS 3KW

    GEESYS  Plus 3KW

    GEESYS  5KW

    RATED POWER

    2000 W

    3000 W

    3000 W

    5000 W

    GRID-TIE OPERATION

    PV INPUT (DC)

    Maximum DC Power

    2250W

    3200W

    4500W

    7500W

    Nominal DC Voltage / Maximum DC Voltage

    300 VDC / 350 VDC

    360 VDC / 500 VDC

    Start-up Voltage / Initial Feeding Voltage

    80 VDC / 120 VDC

    116 VDC / 150 VDC

    MPP Voltage Range

    150 VDC ~ 320 VDC

    250 VDC ~ 450 VDC

    Number of MPP Trackers / Maximum Input Current

    1 / 1 x 15 A

    1 / 1 x 13 A

    1 / 1 x 18 A

    2 / 2 x 15 A

    GRID OUTPUT (AC)

    Nominal Output Voltage

    101/110/120/127 VAC

    208/220/230/240 VAC

    Output Voltage Range

    88 - 127 VAC*

    184 - 264.5 VAC*

    Nominal Output Current

    18 A

    13 A

    13 A

    21 A

    Power Factor

    > 0.99

    EFFICIENCY

    Maximum Conversion Efficiency (DC/AC)

    95%

    96%

    96%

    96%

    European Efficiency@ Vnominal

    94%

    95%

    95%

    95%

    OFF-GRID OPERATION

    AC INPUT

    AC Start-up Voltage/Auto Restart Voltage

    60 - 70 VAC / 85 VAC

    120 - 140 VAC / 180 VAC

    120 - 140 VAC / 180 VAC

    120 - 140 VAC / 180 VAC

    Acceptable Input Voltage Range

    80 - 130 VAC

    170 - 280 VAC

    170 - 280 VAC

    170 - 280 VAC

    Number of MPP Trackers / Maximum Input Current

    30 A

    40 A

    PV INPUT (DC)

    Maximum DC Voltage

    350 VDC

    500 VDC

    MPP Voltage Range

    150 VDC ~ 320 VDC

    250 VDC ~ 450 VDC

    Maximum Input Current

    1 / 1 x 15 A

    1 / 1 x 13 A

    1 / 1 x 18 A

    2 / 2 x 15 A

    BATTERY MODE OUTPUT (AC)

    Nominal Output Voltage

    101/110/120/127 VAC

    202/208/220/230/240 VAC

    Output Waveform

    Pure Sinewave

    Efficiency (DC to AC)

    90%

    93%

    93%

    91%

    HYBRID OPERATION

    PV INPUT (DC)

    Nominal DC Voltage / Maximum DC Voltage

    300 VDC / 350 VDC

    360 VDC / 500 VDC

    Start-up Voltage / Initial Feeding Voltage

    80 VDC / 120 VDC

    116 VDC / 150 VDC

    MPP Voltage Range

    150 VDC ~ 320 VDC

    250 VDC ~ 450 VDC

    Maximum Input Current

    1 / 1 x 15 A

    1 / 1 x 13 A

    1 / 1 x 18 A

    2 / 2 x 15 A

    GRID OUTPUT (AC)

    Nominal Output Voltage

    101/110/120/127 VAC

    208/220/230/240 VAC

    Output Voltage Range

    88-127 VAC*

    184 - 264.5 VAC*

    Nominal Output Current

    18 A

    13 A

    13 A

    21 A

    AC INPUT

    AC Start-up Voltage / Auto Restart Voltage

    60 - 70 VAC / 85 VAC

    120 - 140 VAC / 180 VAC

    120 - 140 VAC / 180 VAC

    120 - 140 VAC / 180 VAC

    Acceptable Input Voltage Range

    80 - 130 VAC

    170 - 280 VAC

    170 - 280 VAC

    170 - 280 VAC

    Maximum AC Input Current

    30 A

    40 A

    BATTERY MODE OUTPUT (AC)

    Nominal Output Voltage

    101/110/120/127 VAC

    202/208/220/230/240 VAC

    Efficiency (DC to AC)

    90%

    93%

    93%

    91%

    BATTERY & CHARGER

    Nominal DC Voltage

    48 VDC

    Maximum Charging Current

    25A

    60A

    GENERAL

    PHYSICAL

    Dimension, D X W X H (mm)

    420 x 415 x 170

    505 x 440 x 135

    Net Weight (kgs)

    15.5

    18.5

    INTERFACE

    Communication Port

    RS-232/USB

    Intelligent Slot

    Optional SNMP, Modbus, and AS-400 cards available

    ENVIRONMENT

    Humidity

    0 ~ 90% RH (No condensing)

    Operating Temperature

    0 to 40oC

    0 to 40°C

    -10 to 55°C

    Altitude

    0 ~ 1000 m**

    Applications:

    • Domestic Applications
    • Corporate Applications
    • Institutional Applications
    Trade Information
    • Letter of Credit at Sight (Sight L/C), Cheque, Cash in Advance (CID), Cash Advance (CA)
    • Asia
    • All India
    Contact Us

    No.33A, Alandur Road, Saidapet, Chennai, Tamil Nadu, 600015, India
    Phone :+918037405153